DVP15MC11T is a multi-axis motion controller based on CANopen communication protocol.

Follows the CANopen DS301 basic communication protocol and DSP402 motion control protocol,

Built-in motion instructions (motion instructions support BufferMode and Jerk),

It is flexible and convenient to use, allowing users to quickly learn and quickly develop projects.

The DVP15MC11T controller can control up to 24 real axes through the CANopen (Motion) interface.

Supports single-axis motion instructions related to speed, position, torque, origin return, etc.

Supports multi-axis commands such as electronic gear, electronic cam, rotary cutting, G code, etc.

Feature of product

  • Can control up to 24 real axes, virtual axis number range: 1~32, cannot be repeated with the real axis number
  • Built-in motion commands, supporting Jerk and BufferMode, making it flexible and convenient to use
  • Supports encoder axis and virtual axis
  • Supports single-axis commands such as speed, position, origin return, torque, position setting, etc.
  • Supports electronic gears and electronic cams
  • Supports application instructions such as rotary cutting
  • Support G code: 8-axis linear interpolation, arc interpolation, helical interpolation
  • Support coordinate motion commands

Technical specifications

  1. 1GHZ high-speed floating point arithmetic processor
  2. High calculation accuracy: supports LREAL (double precision floating point) data type calculations
  3. 4-axis synchronization time is 2 ms, 8-axis synchronization time is 4 ms
  4. Program capacity: 20 MB
  5. Variable capacity: 20 MB
  6. 1 CANopen communication port (can be used as CANopen master station or slave station)
  7. 1 CANopen (Motion) communication port (dedicated to motion control)
  8. External input and output points (16 points for high-speed input and 8 points for high-speed input and output)
  9. 2 incremental encoder interfaces
  10. 1 SSI absolute encoder interface
  11. Two independent Ethernet communication ports
  12. 1 SD card slot 1 RS-232 communication port and 1 RS-485 communication
  13. Left expansion: 8 DVP-S series left modules can be expanded
  14. Right expansion: DVP-S series right module can be expanded (240 input points and 240 output points, 8 special modules)